HP 50.x Fuser Error on the P4014, P4015 and P4515
Quick answer: A 50.1, 50.2, 50.3 or 50.4 error on a P4014, P4015 or P4515 is a fuser problem until proven otherwise. Reseat the fuser and use a wall outlet. We carry the remanufactured RM1-4554 fuser and the CB388A maintenance kit (remanufactured and OEM).
What the error means
These workgroup LaserJets use the same 50.x fuser codes as the rest of the HP mono line. 50.2 (warmup) is the one you will see most often. The fuser in this family is RM1-4554 (RM1-4554-000). The CB388A maintenance kit, rated at 225,000 pages on the manufacturer listing, includes the fuser and the rollers that wear with it.
What to try before you order a part
- Turn the printer off and unplug it. Let the fuser cool — the rear door area gets very hot.
- Open the rear door, pull the fuser, and reinstall it until it is fully seated.
- Power the printer from a wall outlet.
- If 50.x returns, replace the fuser, or install the CB388A kit if the printer has also asked for a maintenance kit.
The part we carry
We carry a remanufactured RM1-4554 fuser (manufacturer listing: 100,000 pages) and the CB388A maintenance kit remanufactured and OEM (manufacturer listing: 225,000 pages). Remanufactured parts are up to 40% less than OEM. An OEM-only fuser for this family is not in the current catalog; the kit is the OEM path.
After you install it
After you install the CB388A kit, reset the maintenance count from the printer’s configuration or resets menu. The exact key sequence is in the P4014/P4015/P4515 user guide for your control panel. If you only replaced the fuser to clear a 50.x error and the printer had not reached its kit interval, you may not need a count reset.
FAQ
Which fuser fits a P4015?
RM1-4554 (also listed as RM1-4554-000). We carry a remanufactured unit. The CB388A kit includes the fuser plus rollers.
What does 50.2 mean on a P4015?
Warmup failure. Reseat the fuser; if the error returns, replace it.
Do you carry the OEM kit?
Yes. We carry OEM CB388A and a remanufactured CB388A kit with aftermarket parts. Remanufactured is up to 40% less than OEM.
How do I clear Perform Printer Maintenance after the kit is in?
Reset the maintenance count in the configuration or resets menu. Use the steps in the user guide for your panel; do not skip the reset or the message will stay.