HP 50.x Fuser Error on the M506, M507 and M527

Quick answer: A 50.x fuser error on an M506, M507, M527 or M528 is usually the fuser. Reseat it, use a wall outlet, and replace it if the code returns. We carry the 110V RM2-5679 fuser remanufactured and OEM, and a remanufactured maintenance kit listed for the M506 and M527.

What the error means

The M506 family uses the same 50.1 / 50.2 / 50.3 / 50.4 fuser codes. The 110V fuser is RM2-5679. The manufacturer listing rates it at 150,000 pages. This fuser is also listed for the M507, the M527 and M528 MFPs, and the Pro M501 in the remanufactured listing.

What to try before you order a part

  1. Power off, unplug, and let the fuser cool.
  2. Reseat the fuser until it latches on both sides.
  3. Power from a wall outlet.
  4. If 50.x returns, replace the RM2-5679 fuser. If the printer is also due for rollers, use the maintenance kit instead.

The part we carry

We carry a remanufactured RM2-5679 fuser and the OEM 110V RM2-5679 fusing assembly, plus a remanufactured maintenance kit listed for the M506 and M527. The manufacturer listing rates the fuser and kit at 150,000 pages. Remanufactured parts are up to 40% less than OEM. The remanufactured kit row in the catalog does not list a separate OEM kit number, so match your printer model carefully.

The OEM RM2-5679 listing is the 110V assembly. Confirm you are not ordering for a 220V printer.

After you install it

After a kit install, reset or confirm the maintenance count using the supplies menu for your firmware. If you only replaced the fuser to clear a 50.x error, the warmup message should be gone at power-on.

FAQ

Which fuser fits the M506 and M527?

RM2-5679, 110V. We carry remanufactured and OEM.

Does this also fit the M501 or M507?

The remanufactured listing includes the Pro M501 and the M507 / M528 family as well as the M506 and M527. Check the model on the printer label against the product page.

What yield is listed?

The manufacturer listing rates the RM2-5679 fuser at 150,000 pages. Actual pages vary with what you print.

Do you carry an OEM maintenance kit for the M506?

The current catalog has a remanufactured M506/M527 kit and the OEM RM2-5679 fuser. We do not invent an OEM kit part number that is not in the listing.