HP 50.4 Fuser Error on the M607, M608 and M609
Quick answer: 50.4 is a fuser fault, but on many LaserJets it is also the code you get from bad line voltage or a UPS. Plug the printer into a wall outlet first. If 50.4 continues, replace the fuser. We carry the RM2-1256 fuser and the L0H24A kit for the M607 family.
What the error means
50.4 is a fuser error that often tracks with power quality as well as a failed fuser. HP documentation for older LaserJets ties 50.4 to low or unstable line voltage (a UPS is a frequent cause). On the M607 family, treat it as a fuser-or-power problem: rule out the outlet, then replace the fuser if the code remains.
What to try before you order a part
- Unplug the printer from any UPS, power conditioner, or overloaded strip. Plug it into a wall outlet.
- Turn it off, let the fuser cool, reseat the fuser, and turn it on.
- If 50.4 returns on a known-good outlet, replace the fuser.
- If a replacement fuser still fails, the low-voltage power supply is the next suspect.
The part we carry
We carry the 110V RM2-1256 fuser remanufactured and OEM, and the L0H24A maintenance kit remanufactured and OEM. Remanufactured parts are up to 40% less than OEM.
- Remanufactured HP RM2-1256 Fuser
- Remanufactured HP L0H24A Maintenance Kit with Aftermarket Parts
- OEM HP L0H24-67901 Maintenance Kit
Use the 110V RM2-1256 / L0H24A unless your printer is a 220V unit.
After you install it
If the 50.4 was only a power issue, you may not need a part at all. If you did replace the fuser or kit, this family clears the maintenance count automatically after about 100 pages. There is no reset menu.
FAQ
Can a UPS cause a 50.4 fuser error?
Yes. Try a wall outlet before you order a fuser. Unstable or stepped-down power can throw 50.4 even when the fuser is fine.
If it is not the outlet, what do I replace?
The RM2-1256 fuser. The L0H24A kit is the better order if the printer is also due for its paper-path rollers.
Is 50.4 the same as 50.2?
No. 50.2 is a warmup timeout. 50.4 is a fuser fault that is also commonly tied to line voltage. Both can still end in a fuser replacement if power is good.
Do I reset a counter after I replace the fuser?
Not from a menu on the M607, M608 or M609. Print about 100 pages and the fuser chip should clear the count.